Internally, AthenaPK (and almost all MHD codes) use Heaviside-Lorentz units, where the magnetic field is transformed from$B \rightarrow B / \sqrt{4 \pi}$ . (See also the note in the Castro documentation about this.)
So when converting from CGS-Gaussian units to code units, it is necessary to divide by$\sqrt{4 \pi}$ (in addition to the base dimensional factors).
When converting from code units to CGS-Gaussian units, it is necessary to multiply by$\sqrt{4 \pi}$ (in addition to the base dimensional factors).